Our Products
We supply and install the following anhydrite liquid screed products
Product | Characteristic Strength | Substrate | Absolute Min Depth | Recommended Depth | Applications |
---|---|---|---|---|---|
Standard | C25-F4 | Slab and membrane | 30mm | 30mm | Standard levelling screed on a membrane |
Standard | C25-F4 | Insulation domestic | 35mm | 40mm | Over insulation in domestic properties |
Standard | C25-F4 | Insulation commercial | 40mm | 40mm | Over insulation in commercial building |
Standard | C25-F4 | UFH | 45mm | 50mm | Over UFH and insulation & membrane |
Timber | C35/F6 | Timber floors, lewis decking | 40mm | 40mm | On a timber deck, with insulation on a deck |
Timber | C35/F6 | Timber deck with UFH | 45mm | 45-50mm | On a timber deck, with insulation on a deck & UFH, 25mm cover to pipe as minimum |
Extra | C35-F6 | Slab and membrane, insulation and membrane, areas of high foot traffic, UFH | 45mm | 50mm | Garage floors, areas of high foot traffic, timber floors, schools, hospitals, etc. |
Thermal | C35-F6 | Insulation with UFH, slab with UFH * (timber with UFH at 45mm) |
40mm* | 40mm + | Minimum 20mm over UFH pipe (Cannot be used on a timber floor at 40mm. Has to be 45mm) |
TS20 | C35-F5 | Slab and membrane only | 20mm | 20mm + | Cannot be used on insulation at 20mm. But can be laid on proprietary low profile heating systems subject to the specification. 20mm cover to the pipes. |
Rapide | C35-F6 | Slab and membrane, insulation and membrane, areas of high foot traffic, over UFH | 40mm | 50mm | shown to be dry in 14 days at 50mm. Can be laid at 40mm with no UFH, can be laid with UFH if a deep screed is required, but this won't dry in 14 days. |